upsilon/gateware/rtl/control_loop/control_loop_sim_interactiv...

173 lines
4.0 KiB
C++
Raw Normal View History

#include <memory>
#include <limits>
#include <cstdint>
#include <cstring>
#include <cstdlib>
#include <iostream>
#include <random>
#include <unistd.h>
// Other classes implemented (Verilator)
#include <verilated.h>
#include "control_loop_math_implementation.h"
#include "control_loop_cmds.h"
#include "Vcontrol_loop_sim_top.h"
using ModType = Vcontrol_loop_sim_top;
// Clock
uint32_t main_time = 0;
double sc_time_stamp() {
return main_time;
}
ModType *mod;
static void run_clock() {
for (int i = 0; i < 2; i++) {
mod->clk = !mod->clk;
mod->eval();
main_time++;
}
}
static void init(int argc, char **argv) {
Verilated::commandArgs(argc, argv);
Verilated::traceEverOn(true);
mod = new ModType;
mod->clk = 0;
}
static void set_value(V val, unsigned name) {
mod->cmd = CONTROL_LOOP_WRITE_BIT | name;
mod->word_into_loop = val;
mod->start_cmd = 1;
do { run_clock(); } while (!mod->finish_cmd);
mod->start_cmd = 0;
run_clock();
}
int main(int argc, char **argv) {
init(argc, argv);
int Con, // Continue option for user
P = 3, // Default P value
I = 0, // Default I value
Delay = 20, // Default Delay value
SetPt = 10000, // Default SetPt value
Status = 1, // Default Status value
Option_Picked; // Option user picked
do
{
mod = new ModType;
Transfer func = Transfer{150, 0, 2, 1.1, 10, -1};
mod->clk = 0;
// Testing this char for P value
char Data_Change_S = '0b11010111000010100011110101110000101000111';
// Default value for P, some type of error where it won't accept any string, int | Try char next time
set_value(0b11010111000010100011110101110000101000111, CONTROL_LOOP_P);
// Default value
set_value((V)6 << CONSTS_FRAC, CONTROL_LOOP_I);
set_value(Delay, CONTROL_LOOP_DELAY);
set_value(SetPt, CONTROL_LOOP_SETPT);
set_value(Status, CONTROL_LOOP_STATUS);
// Menu
do
{
printf("%15s\n", "Menu");
printf("1) Set Control loop P Current value: %d\n", P);
printf("2) Set Control loop I Current value: %d\n", I);
printf("3) Set Delay Current value: %d\n", Delay);
printf("4) Set setpoint Current value: %d\n", SetPt);
printf("5) Set status Current value: %d\n", Status);
printf("6) Continue\n");
// Checks for what option user picks
scanf("%d", &Option_Picked);
// Clears unix screen
system("clear");
switch (Option_Picked)
{
case 1:
// This case doesn't work for some reason? Need further time to figure it out
printf("Please input new Control Loop P value: ");
scanf("%d", &P);
set_value(P, CONTROL_LOOP_P);
break;
case 2:
printf("Please input new Control Loop I value: ");
scanf("%d", &I);
set_value(I, CONTROL_LOOP_I);
break;
case 3:
printf("Please input new delay value: ");
scanf("%d", &Delay);
set_value(Delay, CONTROL_LOOP_DELAY);
break;
case 4:
printf("Please input new setpoint value: ");
scanf("%d", &SetPt);
set_value(SetPt, CONTROL_LOOP_SETPT);
break;
case 5:
printf("Please input new status value: ");
scanf("%d", &Status);
set_value(Status, CONTROL_LOOP_STATUS);
break;
}
} while (Option_Picked != 6);
mod->curset = 0;
// Resets Con to 1 to activate for loop
Con = 1;
for (int tick = 0; Con == 1; tick++) {
run_clock();
if (mod->request && !mod->fulfilled) {
/* Verilator values are not sign-extended to the
* size of type, so we have to do that ourselves.
*/
V ext = sign_extend(mod->curset, 20);
V val = func.val(ext);
printf("setting: %ld, val: %ld\n", ext, val);
mod->measured_value = val;
mod->fulfilled = 1;
} else if (mod->fulfilled && !mod->request) {
mod->fulfilled = 0;
}
if (mod->finish_cmd) {
mod->start_cmd = 0;
}
// After 100000 ticks shows user prompt, might make tick to be changable for user.
if (tick % 100000 == 0 && tick != 0)
{
printf("Continue? (0 for exit, 1 for yes, 2 to return to menu)\n");
scanf("%d", &Con);
}
}
// Clears unix screen
system("clear");
mod->final();
delete mod;
} while (Con == 2);
return 0;
}