Auto-precharge now only fires when it needs to

This commit is contained in:
2018-05-03 03:34:21 -04:00
parent c23814961d
commit d0fcfb172f
1 changed files with 40 additions and 4 deletions

View File

@ -35,7 +35,21 @@ class BankMachine(Module):
ba = settings.geom.bankbits
self.cmd = cmd = stream.Endpoint(cmd_request_rw_layout(a, ba))
row_last = Signal(settings.geom.rowbits);
auto_precharge = Signal()
# # #
slicer = _AddressSlicer(settings.geom.colbits, address_align)
# Row Change buffer
# Note: This would be a lot better if we could instead peek at the next value from cmd_buffer
rowchg_buffer_layout = [("differentRow", 1)]
if (settings.cmd_buffer_depth-1) < 2:
rowchg_buffer = stream.Buffer(rowchg_buffer_layout)
else:
rowchg_buffer = stream.SyncFIFO(rowchg_buffer_layout,
settings.cmd_buffer_depth-1)
self.submodules += rowchg_buffer
# Command buffer
cmd_buffer_layout = [("we", 1), ("adr", len(req.adr))]
@ -44,6 +58,7 @@ class BankMachine(Module):
else:
cmd_buffer = stream.SyncFIFO(cmd_buffer_layout,
settings.cmd_buffer_depth)
self.submodules += cmd_buffer
self.comb += [
req.connect(cmd_buffer.sink, omit=["wdata_valid", "wdata_ready",
@ -52,8 +67,19 @@ class BankMachine(Module):
cmd_buffer.source.ready.eq(req.wdata_ready | req.rdata_valid),
req.lock.eq(cmd_buffer.source.valid),
]
slicer = _AddressSlicer(settings.geom.colbits, address_align)
#Set row change buffer
self.comb += [
rowchg_buffer.sink.differentRow.eq(slicer.row(req.adr) != row_last),
rowchg_buffer.sink.valid.eq(cmd_buffer.source.valid & cmd_buffer.sink.valid & cmd_buffer.sink.ready),
rowchg_buffer.source.ready.eq(cmd_buffer.source.ready),
auto_precharge.eq(rowchg_buffer.source.differentRow & rowchg_buffer.source.valid),
]
self.sync += [
If(cmd_buffer.sink.valid & cmd_buffer.sink.ready,
row_last.eq(slicer.row(req.adr))
)
]
# Row tracking
has_openrow = Signal()
@ -77,7 +103,7 @@ class BankMachine(Module):
If(sel_row_adr,
cmd.a.eq(slicer.row(cmd_buffer.source.adr))
).Else(
cmd.a.eq(slicer.col(cmd_buffer.source.adr))
cmd.a.eq((auto_precharge << 10) | slicer.col(cmd_buffer.source.adr))
)
]
@ -107,7 +133,10 @@ class BankMachine(Module):
req.rdata_valid.eq(cmd.ready),
cmd.is_read.eq(1)
),
cmd.cas.eq(1)
cmd.cas.eq(1),
If(cmd.ready & auto_precharge,
NextState("AUTOPRECHARGE")
)
).Else(
NextState("PRECHARGE")
)
@ -116,6 +145,13 @@ class BankMachine(Module):
)
)
)
fsm.act("AUTOPRECHARGE",
If(self.precharge_timer.done,
cmd.valid.eq(0),
NextState("TRP")
),
track_close.eq(1)
)
fsm.act("PRECHARGE",
# Note: we are presenting the column address, A10 is always low
If(self.precharge_timer.done,