enjoy-digital
df23b3f8cd
Merge pull request #41 from smunaut/proto
...
core: Change upload protocol to allow bursting through xBone
2022-03-14 09:33:06 +01:00
Sylvain Munaut
c5137773f6
core: Change upload protocol to allow bursting through xBone
...
Instead of using a very wide CSR, we force it to max 32 bits
and read each captured words as several sub-words.
Also, instead of checking for 'valid' flag every time, we
just read the 'level' of the memory buffer. Given the way
LiteScope works, we know capture is done and this is how many
words there is to read.
All in all this means that reading the data off the
buffer is just reading the same address over and over meaning
we can use very long bursts which helps _a_lot_ to speed things
up.
Signed-off-by: Sylvain Munaut <tnt@246tNt.com>
2022-03-09 22:07:27 +01:00
Florent Kermarrec
6f0287fecd
core: Fix default samplerate and convert to int.
2022-03-07 17:39:31 +01:00
enjoy-digital
71187f8bd0
Merge pull request #40 from jevinskie/jev/vcd-timescale-fix
...
VCD: Add samplerate support to fix displayed timestamps
2022-01-31 16:55:12 +01:00
Jevin Sweval
21f6fcaa28
VCD: Add samplerate support to fix displayed timestamps
...
To use this, pass the samplerate kwarg to LiteScopeAnalyzer(). If using the sys domain, soc_obj.sys_clk_freq works.
2022-01-29 13:44:27 -08:00
Florent Kermarrec
42a357714b
ci: Install ninja-build/meson.
2022-01-05 09:24:43 +01:00
Florent Kermarrec
769b9b6e61
Bump year.
2022-01-05 09:07:13 +01:00
Florent Kermarrec
08072a78ba
Copyrights: Bump year.
2021-08-31 17:48:07 +02:00
Florent Kermarrec
14e8af8dd9
CONTRIBUTORS: Update.
2021-08-31 17:47:36 +02:00
Florent Kermarrec
45f562d63c
core/LiteScopeAnalyzer: Switch register parameter to boolean.
2021-08-25 14:09:53 +02:00
enjoy-digital
1596bff127
Merge pull request #30 from antmicro/jboc/registered-inputs
...
litescope/core: add option to register input signals to cut timings
2021-08-25 13:23:59 +02:00
enjoy-digital
405b912829
Merge pull request #31 from sthornington/master
...
Fix the cli error messages to make it clearer when you need to provide more CSVs
2021-08-25 13:17:15 +02:00
enjoy-digital
bf1c37864a
Merge branch 'master' into master
2021-08-25 13:17:08 +02:00
enjoy-digital
ea431069f7
Merge pull request #36 from DurandA/clear-scope
...
litescope/core: add function to clear scope
2021-08-25 13:16:43 +02:00
Florent Kermarrec
431c730874
software/dump/json: Fix typo.
2021-08-25 13:06:00 +02:00
enjoy-digital
9437f52233
Merge pull request #35 from DurandA/json-exporter
...
software/dump: add JSON dump
2021-08-25 13:05:20 +02:00
Arnaud Durand
1243ab3c81
software/dump: add JSON dump
2021-05-24 03:57:58 +02:00
Arnaud Durand
fab60ab5e0
litescope/core: add function to clear scope
...
The analyzer driver can be reused for further capturing by calling
the clear() function.
2021-05-24 03:57:03 +02:00
Florent Kermarrec
72c9930705
test/test_examples: Update.
2021-05-03 12:12:16 +02:00
Simon Thornington
fe515d43e8
fix test, broken by the vendor_ prefixing of the platform artifacts
2021-04-10 19:04:38 -04:00
Simon Thornington
1e5305a2a4
trivial change
2021-04-10 18:58:42 -04:00
Simon Thornington
53637af809
fix typo
2021-04-10 13:59:27 -04:00
Simon Thornington
ad2a781681
fix value conversion for hex values
2021-04-10 13:58:32 -04:00
Simon Thornington
2f37678b61
optional parameter to pass in the SoC CSR CSV, in addition to the analyzer CSV, necessary if the SoC was build with a --csr-csv other than csr.csv. Also improve the error messages a bit.
2021-04-10 13:07:14 -04:00
Jędrzej Boczar
824985cdd3
litescope/core: add option to register input signals to cut timings
2021-03-23 09:58:52 +01:00
Florent Kermarrec
f7a9672284
platforms/targets: switch to LiteX-Boards.
2021-01-04 14:14:45 +01:00
Florent Kermarrec
f78400aa29
ci: install RISC-V GCC.
2020-12-17 16:56:31 +01:00
Florent Kermarrec
c8b7e1a922
litescope/core: set default csr_csv to csr_csv="analyzer.csv".
...
Simplify creating basic analyzer:
from litescope import LiteScopeAnalyzer
analyzer_signals = [...]
self.submodules.analyzer = LiteScopeAnalyzer(analyzer_signals, depth=512)
self.add_csr("analyzer")
2020-11-30 15:04:09 +01:00
Florent Kermarrec
0a67448ce9
ci: migrate from Travis CI to Github Actions.
2020-11-24 13:55:54 +01:00
Florent Kermarrec
94e2d15c94
software/litescope_cli: cleanup, use --csv to select analyzer file and add --dump argument.
2020-10-30 11:58:38 +01:00
Florent Kermarrec
e6e5675100
software/litescope_cli: add name support (default="analyzer").
...
We can have several analyzers in the design, this allows selecting the one to use.
2020-10-23 10:31:46 +02:00
Florent Kermarrec
d6911390c0
software/litescope_cli: add group support.
2020-10-16 10:40:24 +02:00
Florent Kermarrec
dc9109030a
software/driver/analyzer/add_trigger: add support for binary/hexa expressions with x support.
...
ex: litescope_cli -v sig1 0b111x0
ex: litescope_cli -v sig2 0x1234567x
2020-09-03 13:16:32 +02:00
Florent Kermarrec
69de7c4930
software/Dump: add add_scope_clk and add_scope_trig methods and add scope_clk/trig to dumps.
2020-09-03 09:23:19 +02:00
Florent Kermarrec
219a90122f
core/Trigger: also apply mask to trigger value (avoid having doing it in software).
2020-09-02 17:09:25 +02:00
Florent Kermarrec
12be70325e
software/litescope_cli: set default length to None (do a capture with max depth).
2020-09-02 10:55:32 +02:00
Florent Kermarrec
bd10138124
core/_Storage: fix size of length/offset signals.
2020-09-02 10:54:38 +02:00
Florent Kermarrec
02b543e5ba
litescope_cli: add capture subsampling support.
2020-08-25 09:28:15 +02:00
Florent Kermarrec
2739d5a069
add SPDX License identifier to header and specify file is part of LiteScope.
2020-08-23 16:45:20 +02:00
Florent Kermarrec
ec7bd6b47d
getting started: update.
2020-08-07 23:10:29 +02:00
enjoy-digital
7d227740bd
Merge pull request #27 from cklarhorst/fix-storage-wrong-clock-domain
...
Fix: 2 signals in the storage class belong to the wrong clock domain
2020-08-07 14:20:14 +02:00
Christian Klarhorst
ad4e46c8c6
Fix: 2 signals in the storage class belong to the wrong clock domain
...
Signals & Domain overview:
- self.{offset,length}.storage belong to sys clock
- offset, length belong to scope clock
- mem belongs to scope clock
Therefore, everything that involves mem needs to use offset/length
2020-08-07 13:56:06 +02:00
enjoy-digital
2ad73a0f54
Merge pull request #25 from cklarhorst/fix-trigger-flush-timer-wrong-clock-domain
...
Fix: A WaitTimer belongs to the wrong clock domain (trigger flush)
2020-08-05 23:10:26 +02:00
Christian Klarhorst
16e65556a2
Fix: A WaitTimer belongs to the wrong clock domain (trigger flush)
...
The WaitTimer for the trigger flush should belong to the scope clock
instead of the sys clock
2020-08-05 16:21:08 +02:00
Florent Kermarrec
0066866000
travis: install riscv toolchain for example.
2020-08-05 15:51:01 +02:00
Florent Kermarrec
6a322ed405
test/test_examples: update.
2020-08-05 14:51:50 +02:00
Florent Kermarrec
bc6c5e35ee
examples: add mininal example on Arty with Etherbone and ibus/counter on analyzer.
2020-08-05 13:22:29 +02:00
Florent Kermarrec
0182377a07
examples: remove obsolete examples rename litescope_test to litescope_cli and add it as console script.
2020-08-05 12:41:50 +02:00
enjoy-digital
a80c964075
Merge pull request #22 from antmicro/jboc/test-script
...
Add a script for testing LiteScope
2020-07-28 11:25:28 +02:00
Jędrzej Boczar
8b0274d2eb
examples: add a more general script for testing
2020-07-24 12:39:11 +02:00